Corrosive exhaust from fume hoods and process lines doesn’t stay contained — it attacks ductwork, rooftop equipment, and anything downstream that isn’t built to resist it. Glorylab’s PP fume hood scrubbers are engineered specifically for this problem, using polypropylene construction and a spray-and-packing design to neutralize acid mist before it leaves your facility. Whether you’re treating exhaust from a single fume hood or multiple corrosive process points, we build a scrubber sized to your airflow and application.

A Manufacturer You Can Rely On

Glorylab is the manufacturing division of Jiangsu Jiahong Laboratory Equipment Co., Ltd. We design and build our fume hood scrubbers in-house, so there’s no distributor markup and no communication gaps between you and the people who build your equipment. Every unit ships factory-direct, and our team works with lab planners, EHS managers, and industrial buyers in 30+ countries to spec systems that match real exhaust conditions—not generic catalog sizing.

Contact Us Now

Enter your inquiry details, We will reply you in 6 hours.

Contact Form Demo (#3)

What Are Fume Hood Scrubbers and Why Do They Matter?

Fume hood scrubbers control pollution in wet air. They can remove acid mist, corrosive gases, and particulates. These scrubbers remove pollution before the exhaust is released to the atmosphere or recirculated. Air is drawn through a vertical tower, enters a spray section, and passes through a bed of PP hollow ball packing. Hollow ball packing creates a large surface area of the packing. The acid mist is absorbed and neutralized before exiting the scrubber, rather than being vented.

Without a proper scrubber, corrosive exhaust air becomes acid rain and corrodes ductwork, fans, and unit housings; this process is much faster than the equipment’s expected service life. A properly sized scrubber protects downstream equipment, keeps exhaust concentrations within allowed environmental discharge limits, and reduces the risk of exposure to personnel and structures.

Featured Product Models

wet fume scrubber
Glorylab
Suzhou, China
OEM Manufacturer
Built for single-point exhaust treatment, JH-FSP001 is sized for one fume hood or a comparable single acid mist source. It's the right choice when you need dedicated scrubbing for one workstation without the cost or footprint of a system-level unit.
PP body, 8mm/10mm wall thickness
Multi-stage spray section + PP hollow ball packing
Max operating temperature: 50°C
DELIXI electrical components
Automatic or manual water replenishment
fume scrubber
Glorylab
Suzhou, China
OEM Manufacturer
JH-FSP002 is a system-level scrubber designed for multi-source corrosive exhaust — chemical process lines, surface treatment operations, electroplating shops, and other applications where several exhaust points feed into one treatment system. It shares the same core scrubbing mechanism as JH-FSP001, scaled and configured for higher or combined airflow.
PP body, 8mm/10mm wall thickness
Multi-stage spray section + PP hollow ball packing
Max operating temperature: 50°C
DELIXI electrical components
Configurable pump type and control setup

How to Choose the Right Fume Hood Scrubber

Match the scrubber to how your exhaust system actually operates. Here are four common scenarios and the models built to handle them.

Single fume hood handling acid digestion or wet chemistry

If you're exhausting a single fume hood for acid digestion or similar wet chemistry, JH-FSP001 is sized for exactly this scenario — one source, one scrubber, and a minimal footprint.

Multiple fume hoods or combined exhaust points

If you're running multiple fume hoods or process exhaust points that need to be treated together, JH-FSP002's system-level design is built to handle combined or multi-source airflow without requiring a separate unit at every point.

Electroplating or surface treatment lines

These processes typically generate continuous corrosive exhaust from multiple stations, making JH-FSP002 the better fit for centralized treatment and higher-duty operation.

Retrofits with limited mechanical space

Both models use a compact vertical tower footprint designed to fit into new builds and retrofits alike; final sizing depends on your airflow requirements.

Not sure which model is right for you?

Send us your exhaust volume, chemical profile, and site layout, and our engineering team will recommend the right model and configuration.

Model Comparison

Specification JH-FSP001 JH-FSP002
Application Single fume hood / single acid mist source Multi-source corrosive exhaust / process lines
Body Material PP (FRP or stainless steel optional) PP (FRP or stainless steel optional)
Wall Thickness 8mm/10mm 8mm/10mm
Max Operating Temperature 50°C 50°C
Pressure Drop ≤500 Pa ≤500 Pa
Electrical Components DELIXI DELIXI
Water Replenishment Automatic/manual Automatic/manual
Chemical Dosing Optional automatic Optional automatic
Pump/Control Configuration Standard Configurable
Best Suited For Individual lab workstations Electroplating, surface treatment, multi-point chemical processes

Applications by Industry

Acid digestion and wet chemistry laboratories
Acid digestion lab with fume hood scrubber system
Pharmaceutical and chemical testing labs
Pharmaceutical lab with corrosive exhaust scrubber
Electroplating and surface treatment lines
Electroplating line with centralized wet scrubber
Chemical processing and multi-point exhaust systems
Chemical processing exhaust system with wet scrubber

Why Choose Glorylab

01

Factory-Direct Pricing

Glorylab manufactures every fume hood scrubber in-house at our facility near Shanghai. With no distributors or intermediaries in the supply chain, your pricing reflects actual production cost rather than a chain of added margins.

02

Built for Corrosive Exhaust Conditions

Our scrubbers are designed specifically for acid mist and corrosive gas treatment, with PP construction that resists the wet, acidic operating environments that cause ordinary metal equipment to degrade over time.

03

Application-Matched Material Options

PP is the standard choice for most acid mist applications, while FRP and stainless steel versions are also available for projects with different structural, environmental, or facility requirements. Our team helps match the material to your actual exhaust conditions before production begins.

04

Genuine Customization Capability

Tower size, airflow capacity, pump specification, water replenishment method, chemical dosing configuration, and control setup can all be adjusted to suit your exhaust system. Glorylab reviews process and installation requirements before production, not after delivery.

05

Export-Ready Shipping to 30+ Countries

All scrubbers are packed and documented for international freight. We export across Asia, the Middle East, Europe, Africa, and the Americas, and can coordinate consolidated shipping for multi-product laboratory or industrial projects.

06

OEM & Private-Label Support

Custom branding, modified dimensions, and OEM/ODM production are available for distributors, contractors, and system integrators. If you need a scrubber built to your own specification or supplied under your own brand, our team can support that directly.

Our Certifications

We hold international authoritative certifications to ensure our equipment meets global market access standards and production quality requirements.

Patent certificate for fume hood
Patent certificate for fume hood
SGS test report for steel lab bench based on SEFA8M B
SGS test report for steel lab bench based on SEFA8M B
SGS test report for fume hood based on ASHRAE110
SGS test report for fume hood based on ASHRAE110
CE certificate for flammable cabinet
CE certificate for flammable cabinet
Certificate of Quality Management System
Certificate of Quality Management System
Certificate of Environment Management System
Certificate of Environment Management System
Our Manufacturing Strength
Glorylab (Jiangsu Jiahong Laboratory Equipment Co., Ltd.) designs and manufactures all anti-vibration tables at its dedicated 25,000 m² production facility near Shanghai.

The plant is equipped with CNC machining centers, a 300-meter automated coating and finishing line, and in-house QC systems covering incoming materials, in-process inspection, and final functional testing. Products are exported to buyers in more than 30 countries and manufactured in compliance with internationally recognized standards including SEFA 8M-2016, EN 14175-3, and ASHRAE 110-2016. Glorylab's engineering team provides direct technical support for product selection, specification review, and custom configuration throughout the procurement process.
Send Inquiry

Customization & Comprehensive After-Sales Support

One-to-One Customization Service

Tower size & airflow configuration

Custom tower dimensions and airflow capacity are available across both models. Glorylab can match the scrubber body size and internal configuration to your exhaust volume, gas type, and installation conditions.

Material, pump & control configuration

PP is standard, with FRP and stainless steel options available for projects with different structural or environmental requirements. Pump specification, water replenishment method, and manual or automatic control setup can also be adjusted to suit your process.

OEM support

OEM/ODM production with custom branding, modified dimensions, and private-label supply is available across both scrubber models for distributors, contractors, and system integrators.

Global After-Sales Support

Technical compatibility review

Before shipment, our technical team reviews each order to confirm tower size, material selection, airflow configuration, and auxiliary options align with your exhaust conditions and site layout.

Installation documentation & spare parts

Each order includes installation guidance and full information on pump configuration, packing media, and spare parts availability to support long-term operation and maintenance.

Multi-product project coordination

For projects combining scrubbers with fume hoods, fans, ductwork, or other Glorylab product categories, our team can coordinate scheduling, documentation, and consolidated shipping to simplify procurement and reduce lead times.

Related Product

FAQs

The JH-FSP001 is designed for single-point acid mist exhaust treatment, such as one laboratory fume hood or a similar dedicated exhaust source. The JH-FSP002 is positioned as a broader system-level scrubber for facilities where corrosive exhaust comes from multiple process points or a centralized exhaust line, such as electroplating, surface treatment, or chemical processing operations.

Both models are designed for acid mist and water-soluble corrosive gases. Typical applications include fume hood exhaust, wet chemistry processes, chemical dosing areas, electroplating lines, surface treatment operations, and other systems where corrosive gas needs to be treated before discharge.

PP is the standard material for both models because it offers strong resistance to wet, acidic operating conditions and is cost-effective for most applications. FRP and stainless steel versions are also available for projects with different structural, environmental, or facility requirements.

PP is the standard choice for most acid mist and corrosive wet exhaust applications. FRP can be suitable where different structural characteristics are preferred, while stainless steel may be specified when a project requires a metal body. The right choice depends on your gas type, concentration, temperature, and installation environment.

Both the JH-FSP001 and JH-FSP002 are rated for a maximum operating temperature of 50°C. If your exhaust stream exceeds this temperature, our team can review your operating conditions and advise on a suitable alternative configuration.

No. Automatic chemical dosing is available as an optional configuration on both models. Standard systems can be supplied with automatic or manual water replenishment, and the dosing setup can be selected based on your operating preference.

Yes. Both models can be configured to integrate with existing laboratory or industrial exhaust systems. During the quotation process, our team can review airflow volume, ducting layout, and installation conditions to confirm the appropriate configuration.

Sizing depends on your airflow volume, gas type, concentration, temperature, and available installation space. Share these details with our team, and we will recommend the right model, tower size, material, and auxiliary configuration for your project.

Routine operation typically involves checking liquid levels, monitoring the pump and spray circulation system, and inspecting the packing media and internal spray section periodically. We provide installation guidance and operating information with each order to support day-to-day use and maintenance.

Yes. Glorylab manufactures both models in-house and supports OEM/ODM production, private-label branding, and export orders. We ship to more than 30 countries and provide the documentation needed for international freight and project delivery.