It’s important to clarify what the JH-600N is designed to do. This unit provides operator and environmental protection — it filters and captures airborne contaminants generated during bench work to reduce operator exposure and prevent contamination of the surrounding lab space. This differs from the JH-600P, which is built for product protection and maintains clean, particulate-controlled airflow to protect samples or materials from external contamination. If your priority is safeguarding the person and the room, the JH-600N is the correct configuration. If your priority is safeguarding the sample itself, the JH-600P is the appropriate choice.
As a factory-direct manufacturer, Glorylab builds, tests, and quality-inspects every JH-600N unit in-house at our Jiangsu Province facility before it ships — giving you direct access to the people who make your equipment, without agents or trading companies in between.
Features
- No ductwork required. The JH-600N filters air internally through HEPA media rather than exhausting it externally, eliminating the need for building modifications or exhaust connections.
- Immediate deployment. With no ductwork or fixed installation, the unit can be placed on a benchtop and used without construction lead time.
- Portable by design. A steel cabinet structure with a built-in handle lets you move the unit between benches, rooms, or facilities as workflow needs change.
- Small footprint. The compact benchtop format suits labs with limited floor and bench space, without requiring a dedicated fume hood bay.
- High-efficiency filtration. A washable, UV-resistant polyester pre-filter captures larger particulates and extends the life of the primary HEPA filter, which is rated at ≥99.999% efficiency at 0.3 microns.
- Adjustable airflow control. Wind speed is adjustable between 0.2–0.6 m/s, allowing operators to tune containment performance to the task at hand.
- Clear operating status. A microcomputer control system with LED display provides a straightforward readout of unit performance.
- Direct visual access. A 5mm UV-resistant tempered glass manual front window gives the operator a clear view of the work area while maintaining a physical barrier.
Who It’s For
- Teaching labs running student experiments that require basic containment but not full ducted infrastructure at every station.
- Pharmacies performing compounding or preparation tasks that call for localized protection in a retail or clinical space not built with lab-grade ventilation.
- QC and testing labs needing a secondary, movable containment point for light-duty tasks without extending existing ductwork.
- Facilities with limited floor space or building constraints where installing a full ducted fume hood isn’t practical.
Technical Specifications
|
Feature |
JH-600N |
|---|---|
|
Applicable Scope |
Protects operator and environment |
|
Airflow Direction |
Vertical |
|
Cleanliness |
Class 100 |
|
High Efficiency Filter |
≥99.999% @ 0.3μm |
|
Colony Count |
≤0.5/vessel (Petri dish Ø90 mm) |
|
Wind Speed |
>0.5 m/s |
|
Wind Speed Range |
0.2–0.6 m/s |
|
Noise Level |
≤62 dB |
|
Vibration Semi-Peak Value |
≤3 μm |
|
Work Surface Bearing |
10 kg |
|
Composition |
|
|
Inner Chamber |
SUS304 stainless steel plate |
|
Outer Shell |
Cold-rolled steel, electrostatic spraying |
|
Operation Door |
Tempered glass |
|
Operation Door Maximum Opening |
310 mm |
|
Pre-Filter |
Polyurethane (washable, UV-resistant) |
|
LED Lamp |
8W × 1 |
|
UV Lamp |
8W × 1 |
|
Top Fan |
90W, one piece |
|
Controller |
|
|
Display |
LED |
|
Wind Speed Control |
Intelligent, multi-level adjustable |
|
Additional Function |
One-key light/sterilization control |
|
Dimensions |
|
|
Inner Size (W × L × H) |
480 × 340 × 370 mm |
|
Exterior Size (W × L × H) |
550 × 460 × 700 mm |
|
Packing Size (W × L × H) |
680 × 590 × 850 mm |
|
Max Power |
110W |
|
Current Rating |
AC220V/0.5A, 50/60Hz |
|
Net/Gross Weight |
36 / 41 kg |
Shipping
As a factory-based manufacturer located near Shanghai, Glorylab exports directly to institutions, contractors, distributors, and procurement teams worldwide. If your order includes products across multiple categories, we coordinate production schedules to consolidate everything into a single export shipment — reducing your freight costs and simplifying customs clearance. Export packaging is designed and verified to withstand international transportation. Contact us for a shipping quote and estimated delivery timeline based on your destination.
Policies
We can accommodate custom dimensions, materials, and configurations at no extra design cost—submit your technical drawings or room layout when requesting a quote, and our team will review fit and compatibility before production begins. For OEM or private-label packaging requirements, contact us directly to discuss documentation and branding needs.
Frequently Asked Questions
What’s the difference between the JH-600N and the JH-600P?
The JH-600N is built for operator and environment protection — it captures and filters airborne contaminants to protect the person working at the bench and the surrounding lab space. The JH-600P is built for product protection, maintaining controlled airflow to protect the sample or material being handled from outside contamination. The two units serve different purposes and shouldn’t be used interchangeably.
Can the JH-600N replace a full ducted fume hood?
No. It’s designed for light-duty, localized containment where a full-scale ducted fume hood isn’t required or practical — not as a substitute for high-hazard chemical work that requires full ducted exhaust.
Does the JH-600N require any building modifications or ductwork?
No. It operates as a self-contained ductless unit using internal HEPA filtration, so it can be placed on a benchtop and used immediately without exhaust connections or construction.
Can the unit be moved between rooms or benches?
Yes. The steel cabinet structure includes a built-in handle specifically for relocation, allowing the unit to be repositioned as lab layouts or project needs change.
What kind of maintenance does the filtration system need?
The polyester pre-filter is washable and UV-resistant, allowing for regular cleaning and reuse. Inspect and replace the HEPA filter according to standard service intervals based on usage.
Is this suitable for teaching labs or pharmacies?
Yes. Its compact footprint, portability, and lack of ductwork requirements make it well suited to space-constrained environments such as teaching labs and pharmacy compounding areas, where light-duty containment is needed without full infrastructure investment.
Can dimensions or materials be customized for my project?
Yes. Custom specifications are part of our standard manufacturing process at no additional design cost. Submit your requirements when requesting a quote, and our team will review them before production begins.